Manual – LDB 1.5
Page 59
59
Elevator main building
Name of the lock of the SmartRelay belonging to the Output
Module
Mod#0
Address of the SmartOutput Module
Out#5
Address of the output of the SmartOutput Module
Sig#1
Signaling mode active, the output shows the status of output 1
by flashing
SmartOutput Module – Inverting outputs
Since the outputs of the SmartOutput Module are not available as changeover
contacts from a hardware point of view, the software offers you the possibility to
configure the inversion of the Module’s outputs. By checking or un-checking the Invert
outputs box, the output can be defined as a NC or a NO contact.
The relay outputs of the SmartOutput Module are always NC contacts in terms
of their hardware.
Inverting the outputs always applies to the entire Output Module.
Increasing the number of SmartOutput Modules
If you need to add more SmartOutput Modules to your Lock System, then these
should also be assigned to the corresponding SmartRelay type lock.