Simons Voss Technologies Palm LDB Version 1.40 Manuel d'installation Page 154

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 219
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 153
WaveNet Radio Network 3065
Page 11
Backbone wiring:
An RS485 segment (backbone) is wired using a bus comprising a shielded, standard
KAT5 cable. The bus line consists of two data lines (Data+, Data-) and an earth line.
This bus line is connected to every RS485 module associated with a WaveNet Router
in the segment. The RS485 modules are connected to the bus line using a green and
orange 8-pin plug as follows.
6.4 Lock Nodes
WaveNet Lock Nodes form the interface between WaveNet and the locks in the 3060
digital locking and organisation system (locking cylinders and Smart Relays, for
example).
All of them have:
A special B-field port through which they communicate with the
SimonsVoss locks (locking cylinders, control units, furniture locks and so on);
A radio port (868 MHz) for transmitting data to the WaveNet Nodes (WaveNet
Router Nodes, WaveNet Repeater Nodes and WaveNet Central Nodes, for
instance).
orange
green
Vue de la page 153
1 2 ... 149 150 151 152 153 154 155 156 157 158 159 ... 218 219

Commentaires sur ces manuels

Pas de commentaire