VdS Shunt lock function 3066
Page 22
3.2 Programming the Deactivation Units (DA)
Click the line in the locking plan above the one where you want to add a deactivation
unit. Select
New Locking. Then give the deactivation unit a name:
Such as Deactivation unit, main entrance
In the field
Type, select Control unit. Click OK & Exit. If you want to set up additional
deactivation units, repeat these steps.
If you always add the deactivation units above the accompanying digital
locking cylinder, you will have a better overview of the system.
Deactivation units do not need any authorizations which means that you do not have
to insert any crosses. Approve your locking system and program the deactivation
units under
Programming Locking.
The deactivation unit needs supply voltage during the programming. You can
provide this with a 9-volt compound battery, for example. Program activation
unit(s) and deactivation units separately from one another. Do not wire the two
components until after you have programmed them successfully.