VdS Shunt lock function 3066
Page 24
4.0 Installation
4.1 Installing the Deactivation Unit
Install the deactivation unit DA in the immediate vicinity of the digital locking cylinder
(no farther than approximately 30 cm or 12 inches). This guarantees optimum
transmission traffic. Align the deactivation unit so that both fastening screws lie in a
horizontal line. Then the antennas point directly to the locking cylinder (refer to the
drawing below).
You can always achieve better ranges if you use FH cylinders (plastic knob
instead of stainless steel).